================================================================================ Note 17.0 LSI-11/23 ECO History 1 reply JAWS::KAISER 365 lines 25-MAR-1985 09:22 -------------------------------------------------------------------------------- +---------------+ +-----------------+ | d i g i t a l | | uNOTE # 017 | +---------------+ +-----------------+ +----------------------------------------------------+-----------------+ | Title: LSI 11/23 ECO History | Date: 19-NOV-84 | +----------------------------------------------------+-----------------+ | Originator: Bob Hessinger | Page 1 of 8 | +----------------------------------------------------+-----------------+ This micronote documents the ECO and etch revision history of the KDF11-A (LSI 11/23) module. A quick verify has been included so that the status of a module may be determined by a visual check. For the M8186, the revision identifier is a two field alphanumeric designation stamped on the reverse side of the module handle. The first field indicates the etch revision. The second field indicates the modifications to this etch. Hardware revision notation : A 0 Identifies etch level Identifies modifications The M8186 began as hardware revision "A0", as shown above. That is, etch revision "A" with no modifications or rework. As ECO's were released calling for rework, the hardware revision level was updated to "A1", then "A2", etc. Periodically new etch revisions were released, incorporating previous modifications. When these occurred the etch revision field was updated from "A" to "C", and later from "C" to "D". For the M8186, no etch revision "B" was released. Page 2 The hardware revision history of the M8186 is shown below: Release A0 | Rework A1 ECO #1 | | Rework A2 ECO #2 | | NOTE: All modules Rework A3 shipped are at ECO #3 | rev A3 or greater | | NOTE : New etch Relayout +---- C0 rev C created. No ECO #4 | | rev B boards were | | built | | Rework A4 C0 NOTE: Rev C etch incorporates ECO #5 | | changes for ECO #5 | | Rework A5 C1 ECO #6 | | | | Rework A6 C2 ECO #7 | | | | Rework A6 C2 NOTE: This was a documen- ECO #8 | | tation change only | | Rework A7 C3 ECO #9 | | | | Rework and A8 C4 --- D0 Relayout | | | ECO #10 | | | | | | Rework A8 C4 D0 NOTE: This was a ECO #11 documentation change only Page 3 Jumper Functions on Etch Revision "A", "C" and "D" Modules +----------+------------------------------------------------------------+ | Jumper | Function | Description | Shipped | +----------+---------------+-------------------------------+------------+ | W1 | Master Clock | In = Enabled, do not remove | In | +----------+---------------+-------------------------------+------------+ | W2,W3 | DEC Reserved | Factory configured, do not | W2=Out | | | | change (see note 1) | W3=In | +----------+---------------+-------------------------------+------------+ | W4 | BEVENT | Out = Enabled | In | +----------+---------------+-------------------------------+------------+ | W5,W6 | Power-up Mode | Mode W5 W6 | Mode 1 | | | | 0 - PC=24,PS=26 Out Out | W5=In | | | | 1 - Console ODT In Out | W6=Out | | | | 2 - Bootstrap Out In | | | | | 3 - Reserved In In | | +----------+---------------+-------------------------------+------------+ | W7 | Halt/Trap | In = Trap to 10 on Halt | Out | | | Option | Out = Enter Console ODT | | | | | on Halt | | +----------+---------------+-------------------------------+------------+ | W8 | Bootstrap | In = Boot to 17773000 | In | | | Address | Out = Bootstrap address | | | | | specified by jumpers W9-W15 | | +----------+---------------+-------------------------------+------------+ | W9-W15 | User Bootstrap| W9-W15 correspond to address | In | | | Address | bits 9-15 respectively. | | | | | In = logic 1, Out = logic 0 | | +----------+---------------+-------------------------------+------------+ | W16,W17 | DEC Reserved | Factory configured, do not | In | | | | change | | +----------+---------------+-------------------------------+------------+ | Etch A only | +----------+---------------+-------------------------------+------------+ | W18 | DEC Reserved | Factory configured, do not | In | | | | change | | +----------+---------------+-------------------------------+------------+ | W19 |Wake-up Circuit| Out = enabled | In | | | | This jumper is a red wire | | | | | across diode D1 | | +----------+---------------+-------------------------------+------------+ | Etch C and D only | +----------+---------------+-------------------------------+------------+ | W18 |Wake-up Circuit| Out = enabled | In | | | | This jumper is a red wire | | | | | across diode D1 | | +----------+---------------+-------------------------------+------------+ note 1 : W3 on etch A modules consists of a jumper from E2 pin 5 to E2 pin 15. Page 4 +-------------------------------------------------------+ | | | | | | | W18 --- | | | | | | D1 --- | | (W19 - see text) | | | | | | | | | | W17 --- | | +----+ +----+ +----+ +----+ | | | | | | | | | | | | | | | | | | | | W1 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | W16 | | | | | | | | | | | | | | +----+ +----+ +----+ +----+ | | | | W15 --- W2 --- | | W14 --- | | W13 --- | | W12 --- | | W11 --- | | W10 --- | | W9 --- | | W8 --- | | W6 --- | | W7 --- | | W6 --- | | W5 --- W4 --- | | | | | | | | | | | | | | +-+ | ++ +---+ | ++ | | | | +-----------------------+ +-----------------------+ KDF11-A REV A Jumper Layout Page 5 +-------------------------------------------------------+ | | | | | | | | | | | | | | | D1 --- | | (W18 - see text) | | | | | | | | | | +----+ +----+ +----+ +----+ | | | | | | | | | | | | | | | | | | | | W1 --- | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +----+ +----+ +----+ +----+ | | | | W15 --- | | W14 --- | | W13 --- | | W12 --- | | W11 --- | | W10 --- | | W9 --- | | W8 --- | | W6 --- | | W7 --- W4 --- W3 --- | | W6 --- | | W5 --- W2 --- | | | | | | | | | | W16 --- | | W17 --- | | | | +-+ | ++ +---+ | ++ | | | | +-----------------------+ +-----------------------+ KDF11-A REV C Jumper Layout Page 6 +-------------------------------------------------------+ | | | | | | | | | | | | | | | | | W18 | | | | | | | | | | | | | | +----+ +----+ +----+ +----+ | | | | | | | | | | | | | | | | | | | | W1 --- | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +----+ +----+ +----+ +----+ | | | | W15 --- | | W14 --- | | W13 --- | | W12 --- | | W11 --- | | W10 --- | | W9 --- | | W8 --- | | W6 --- | | W7 --- W4 --- W3 --- | | W6 --- | | W5 --- W2 --- | | | | | | | | | | | | W16 --- | | W17 --- | | +-+ | ++ +---+ | ++ | | | | +-----------------------+ +-----------------------+ KDF11-A REV D Jumper Layout Page 7 The following table details the ECO's issued since the M8186 began to ship to the field. These ECO's are coded "M8186-ML0XX", where "XX" is the ECO number shown below : ECO # Problem Quick Verify -------------------------------------------------------------------------- 04 Too many wires and etch cuts, new etch Module handle will be needed. Note that the jumper locations stamped "Cn" where change for etch Revision C. "n" indicates Note also that etch A boards bring only modifications 18 bits of addressing from the MMU to the Q-BUS, while etch C boards bring all 22 bits of addressing from the MMU to the Q-BUS. 05 I/O page addressing scheme differs from Check for etch cut LSI-11/2 processor. to pins 16 and 18 (rev A boards only) 06 The internal wake-up circuit defeats the Red jumper wire is power sequencing provided by standard installed in parallel DEC power supplies. with D1. 07 CTL/DAT hybrid (57-00000-00) and MMU IC CTL/DAT should be (21-15542-00) were not compatible with 57-00000-01 or higher KEF11-AA floating point option. The FP and MMU should be registers in the MMU were inaccessible, 21-15542-01 or higher and the CTL/DAT data path caused for floating point intermittent errors in floating point compatibility. instructions. Coordinate with EC0 M8186-ML009 08 MMU (21-15542-01) was included as part of Some modules may or the M8186 module. This documentation not have MMUs, change removes the MMU and makes it an depending on the option which is ordered separately. options ordered. Page 8 ECO # Problem Quick Verify ------------------------------------------------------------------------- 09 1) No jumper table in print set (doc only) 1) Table added 2) Crystal oscillator may short to adjacent 2) Manufacturing components includes nylon spacer 3) Possibility of worst case MMU timing 3) Module will have violations. Change configuration W2 removed and W3 of W2 and W3 to adjust timing. This in. On rev A ECO must be installed : modules W3 is a A) When ECO m8186-ML007 is installed wire from E2 pin B) When the KEF11 or FPF11 is installed 5 to E2 pin 15. C) When one of the F-11 chips is replaced D) Whenever unexplained system crashes occur 10 1) Heavily loaded systems lock up during 1) Rev A and Rev C worst case timing between DMA and modules will have interrupt arbitration. Symptoms wires on E2 pins usually occur with DMA options not 2 and 4. Rework manufactured by DEC. included in Rev D. 2) Too many wires and etch cuts, new etch 2) Module handle will needed. Note W18 now uses jumper posts. be stamped "Dn" where n indicates modifications. 11 Documentation updated. Documentation only. ================================================================================ Note 17.1 LSI-11/23 ECO History 1 of 1 BRS01::BRUSCHE 5 lines 9-MAY-1985 02:24 -------------------------------------------------------------------------------- Please note that in all tree jumper layout drawings there is a redundant "W6". The top ones are those that should be disregarded. Johan.